    It adopts imported pressure sensitive chip and selective placement technology;
    High precision, stable, digital calibration adjustment, amplification integrated circuit;
    Zero point, fullness, temperature compensation and linear compensation;
    Wide range of output signal types, 4-20mA / 0-20mA / 0-5V / 10V;
    Industrial grade 2088 cast aluminum alloy explosion-proof shell with reliable strength;
    More than 1 million times of service life;
    It can replace the same type of foreign high voltage products;
    Product description of strain type pressure transmitter:

    Chip:
    It adopts imported pressure sensitive chip and selective placement technology;
    Zero point, fullness, temperature compensation and linear compensation;
    High impedance, high precision and high stability;
    More than 1 million times of service life;
    Signal processing and output:
    24 bit ADC sampling and processing chip;
    DSP digital signal conditioning algorithm;
    Multipoint linear temperature calibration;
    Voltage and current overload protection;
    Standard industrial signal output: 4-20mA (two-wire system), 0-20mA (three wire system), 0-5vdc, 0-10vdc, 0.5-4.5vdc (three wire system);
    Advanced 32 bit microprocessor and 24 bit ADC are adopted
    Structure:
    Thick film structure: deep argon arc welding, connecting elastic material and process joint, high strength, impact resistance and fatigue resistance;
    PU film structure: laser welding, connecting elastic material and process joint, transmitting pressure with silicone oil medium, fast response, fatigue resistance, small range;
    Industrial grade 2088 cast aluminum alloy explosion-proof shell with reliable strength;
    The overall structure is compact, and the process connection mode is diversified (m20x1.5, G1 / 2, ZG1 / 2, 1 / 2NPT (thread diameter ≥ 17mm) DN50, etc.);
    Process connection material: 304 or 316;
    Application:
    Measurement and monitoring of oil pressure, water pressure and air pressure;
    Equipment pressure measurement in industrial / power / Petroleum / automation fields;



    Application fields:
    • Oil pressure system

    • Metallurgical equipment

    • petrochemical industry

    • Petroleum Pipeline

    Specification parameter


    1、 Technical parameters
    Measuring medium: melt, fluid, liquid and gas containing impurities (such as paint, toothpaste, pigment, etc.)
    Pressure form: gauge pressure, absolute pressure
    Range: 0 ~ 0.6, 1, 2, 5, 10, 15, 20, 25, 30, 40, 50, 60, 100 (MPA);
               0~10、20、30、50、100、150、200、300、400、500、600(KPa);
             -100KPa~10KPa~40MPa;
             ±10KPa~±100KPa;
    Comprehensive accuracy: ± 0.25% FS; ± 0.5% FS; ± 1% FS
    Non linear: ≤ 0.25% FS
    Repeatability: ≤ 0.1% FS
    Output signal:
    Current type: 4-20mA two-wire system; 4-20mA / 0-20mA three wire system
    Voltage type: 0-5vdc, 0-10vdc, 0.5-4.5vdc three wire system
    Power supply voltage: 24VDC (9-30vdc)
                          5VDC (0.5-4.5vdc output type)
    Service life: ≥ 1 million times
    Insulation impedance: ≥ 1000m Ω / 100VDC
    Load impedance: current output: ≤ 800 Ω; voltage output: ≥ 50K Ω
    Medium temperature: - 20-80 ℃
    Ambient temperature: - 20 ~ 70 ℃
    Compensation temperature: 0 ~ 70 ℃
    Response time: ≤ 5ms
    Overload pressure: 150% FS
    Failure pressure: 3 times of range (range less than 40MPa); 2 times of range (range greater than 41mpa)
    Electrical connection: direct outgoing line of waterproof fastening nut, supporting explosion-proof electrical connection
    Protection grade: IP65 / IP68
    Connecting cable: four core shielded cable, standard length: 3M
    Connection material: 304 / 316L
    Process connection: m20x1.5, G1 / 2, ZG1 / 2, 1 / 2NPT, DN50 Specifications can be made by users







    Ordering considerations
    Precautions for ordering PT500-2088 products
    1. Product range selection:
    In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the following formula:
    Range = x (1.2-1.5) times of the maximum system pressure;
    The actual measuring pressure range of the product should be 15% - 80% of the range;

    2. Product power supply and output:
    The selection of power supply range is determined according to the output specifications of the product:
    Conventional 4-20mA / 0-20mA, 0-5V / 10V output, DC 12-30vdc power supply;
    General rs485-rtu output, DC 12-30vdc power supply;
    0.5-4.5vdc output, DC 5VDC;

    3. The user should understand the measurement medium characteristics of the product:
    Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);

    4. Users should understand the installation environment and installation method of the product:
    Indoor or outdoor installation;
    Ambient temperature;
    Required sealing level;
    Vibration range of equipment;
    Installation method: thread, flange, special structure;
    Whether the installation space meets the overall dimension of the product;

    Precautions for use
    Product power supply range, 9-30vdc ;
    It is strictly prohibited to use hard objects (such as screwdriver, finger, iron nail, etc.) to make the pressure diaphragm output under pressure measurement;
    The power and signal wires shall be correctly wired according to the specifications of the ordered products;
    During product installation, the stressed part is "process connection hexagon wrench position", and the wrench specification corresponds to hexagon;
    It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the tested system exceed the rated use range of the transmitter;
    Pay attention to protect the outgoing cable of the transmitter. When the span is too large on site, it is recommended to use metal pipe for protection or overhead;
    The pressure transmitter is a precision measuring instrument. Do not impose impact or smash to avoid damaging the core
    The product is installed in a ventilated, dry and non corrosive environment, and installed in the open with protective devices to avoid direct sunlight;
    It is strictly prohibited to enter / leak / soak water in the product instrument, and protective devices shall be installed in the open to avoid direct sunlight;

    Common problem
    Proposal
    Name
    Tel
    QQ
    WeChat
    Mailbox
    Address
    Content
    Foshan puliang Electronic Co., Ltd

    Tel:0757-26619568 Fax: 0757-26619508

    24-hour online technical support:13790092618

    Cloud platform:www.puliangiot.com

    Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

    Copyright©Foshan puliang Electronic Co., Ltd