亚洲国产精品久久久岛国片_看中国真人一级毛片_久re视频在线精品首页_亚洲综合自拍一区中文字幕_午夜成人亚洲理伦片在线观看_国产精品亚洲精品观看不卡_免费裸体无遮挡黄网站免费看_精品少妇熟女aⅴ免费久久_日本少妇综合高清_欧美不卡视频一二三区

Welcome to the website of Foshan puliang Electronic Co., Ltd Mobile           中文   EN
Hot Keywords:Pressuresensor Pressure transmitter level sensor Temperature sensor
PT100-T1 Temperature sensor
Imported PT100 platinum resistor / J, K and e thermocouple temperature core is adopted;
The selected patch process has zero point, full scale and temperature compensation;
Accuracy grade: Grade B, Grade A and grade 1 / 3b are optional;
The product has fast response, sensitive response and high precision;
<
>
  • Product parameters
  • Specification parameter
  • Ordering considerations
  • Precautions for use
  • Common problem
  • Proposal

PT100-T1 Temperature sensor


Model: PT100-T1 temperature sensor
Imported PT100 platinum resistor / J, K and e thermocouple temperature core is adopted;
The selected patch process has zero point, full scale and temperature compensation;
Accuracy grade: Grade B, Grade A and grade 1 / 3b are optional;
The product has fast response, sensitive response and high precision;
Diversified structure: thread installation type, armored type, patch type, plug-in type, flange type, etc;
Air connection IP65 / 68, two wire / three core / four core shielded temperature compensation wire;
304 / 316 / corundum tube / alloy and other shell materials;
Temperature range: - 198 ℃ ~ - 40 ℃ ~ 0 ~ 100 ℃ ~ 500 ℃ ~ 1000 ℃;
Probe rod length / diameter / thread specification / flange size can be formulated;
It can replace foreign high-voltage products of the same type;
PT100-T1 temperature sensor Main applications:
Temperature measurement and monitoring of inner cavity of pipeline / equipment;
Equipment temperature monitoring;
Temperature measurement and control in automation / Agriculture / chemical industry / electric power / meteorology and other fields


Application fields:
  • Intelligent fire control

  • Steam supply system

  • Metallurgical equipment

  • petrochemical industry

  • Petroleum Pipeline

  • Extruder equipment

PT100-T1 Temperature sensor


Measuring medium: liquid and gas (compatible with product process connecting materials)
Pressure form: gauge pressure and absolute pressure
Range:
-50 ℃ ~ 100 ℃ / mainly measuring ambient temperature;
0 ℃ ~ 100 ℃ ~ 500 ℃ / PT100 type measures the temperature of high-temperature medium;
0 ℃ ~ 500 ℃ ~ 1000 ℃ / thermocouple type to measure the temperature of high temperature / ultra-high temperature medium;
Comprehensive accuracy:
PT100 type: Class A, class B, class 1 / 3B
Thermocouple type: class I, II and III
Output signal:
PT100 type: resistance signal (refer to the graduation table)
PT1000 type: resistance signal (refer to the graduation table)
Thermocouple type: MV voltage signal (refer to the graduation table)
Insulation impedance: ≥ 1000 m Ω / 100VDC
Medium temperature:
-50 ℃ ~ 100 ℃ / mainly measuring ambient temperature;
0 ℃ ~ 100 ℃ ~ 500 ℃ / PT100 type measures the temperature of high-temperature medium;
0 ℃ ~ 500 ℃ ~ 1000 ℃ / thermocouple type to measure the temperature of high temperature / ultra-high temperature medium;
Ambient temperature: - 40 ~ 70 ℃
Stability: ≤± 0.5% FS / year
Vibration influence: ≤± 0.25% FS / year (mechanical vibration frequency 20Hz ~ 1000Hz)
Withstand pressure: less than 10 atmospheres in general, customized for special requirements
Protection grade: IP65 / IP68
Connecting material: 304 / 316L / corundum, etc
Process connection: m20x1 5. G1 / 2, specifications formulated by users




Precautions for ordering PT100-T1 temperature sensor

1. Product range selection:
In order to achieve the best effect of product accuracy, service life, stability and other functions, the range of the product is calculated according to the following formula:
Range = x (1.2-1.5) times the maximum temperature of the system;
The actual measuring pressure range of the product should be 15% - 80% of the measuring range;

2. Product output / accuracy level / acquisition method:
Different product specifications and accuracy levels:
PT100 type: Class A, class B, class 1 / 3B
Thermocouple type: class I, II and III
The back-end acquisition mode of the temperature sensor shall match the output of the sensor
PT100 type: resistance signal. The resistance signal of Pt100 can be collected as required by the acquisition instrument or input module or board;
PT1000 type: resistance signal. The resistance signal of PT1000 can be collected as required by the acquisition instrument or input module or board;
Thermocouple type: MV voltage signal. The signal of thermocouple can be collected as required by the acquisition instrument or input module or board;

3. Users need to understand the characteristics of the measuring medium of the product:
Medium specification, medium temperature, medium purity (whether it contains impurities or particles, etc.);

4. Users should understand the installation environment and installation method of the product:
Indoor or outdoor installation;
Ambient temperature;
Sealing grade requirements;
Vibration range of equipment;
Pressure seal mode: taper seal, end face seal, arc seal and spherical seal;
Whether the installation space meets the overall dimension of the product;

Precautions for use of Pt100-T1 temperature sensor

For installation and use, please check whether the relevant parameters of the product label and certificate are consistent with the operating conditions;
When the thermal resistance / thermocouple is installed, its insertion depth shall not be less than 8 ~ 10 times of the outer diameter of the thermal resistance protection tube;
Increase the heating part of thermal resistance / thermocouple as much as possible;
The thermal resistance / thermocouple shall be installed vertically as far as possible to prevent bending and deformation at high temperature.
In order to reduce the error during the use of thermal resistance / thermocouple, the surface of protective sleeve shall be close to the temperature of measured medium as much as possible;
When installing the product, the stressed part is "process connection hexagonal wrench position", and the wrench specification corresponds to the hexagonal wrench position;
It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the measured system exceed the rated service range of the transmitter;
Pay attention to protect the sensor / transmitter cable or compensation wire;
Try to avoid direct access to user devices or electrical appliances causing interference;
Name
Tel
QQ
WeChat
Mailbox
Address
Content